representing Pfaudler pH/ORP Electrodes

Flowing Reference

  Home Up Feedback Contents Search  


See Pfaudler's New Glass/Steel pH/ ORP Technology.......

 

[Under Construction]

 

Home
Up

 

 

       

Longest Life, Lowest Maintenance 

Pfaudler Model 03, 04  and Ring electrodes complete the full spectrum of pH electrodes for applications that can not be measured with the model 18 and 40 electrodes. These electrodes feature the same measuring electrode as found in the model 18 and 40 probes plus they feature a conventional pressurized flowing reference electrode. The pressurized reference solution prevents any penetration of the process into the diaphragm insuring reference voltage stability, thus eliminating drift.

These electrodes are primarily used in processes with a lower pH range (as low as 0-4pH) and applications that do not have a relatively constant sodium ion concentration. 

Since these Electrodes are calibrated with standard buffers they are suitable for vessels that produce many different processes. 

The flange mounting 03 & 04 electrodes are available in various lengths (12" - 126") to meet all process needs. The ring electrode mounts directly in a (2" or 3") pipe providing an un-obstructive process mounting. 

These electrodes are totally glass coated which includes the flange mounting. They have external reference electrolyte reservoirs for easy maintenance. A Teflon gasket completes the seal without any metal parts.       

Applications

bulletDifficult Chemical Processes containing sulfides
bulletPulp and Paper.... Bleaching, Washers, Fiberglass Piping
bulletChemical.... Glass Lined Reactors, Glass Lined Piping, Non-Metal Piping 
bulletBio-Reactors.... Glass Lined Reactors, Glass Lined Piping
bulletStainless Reactors

 

    "Pressurized Flowing Reference Electrodes 

 Model 03 & 04 Electrodes...Ring Type Electrode 

 Variable Insertion Length.......Inline Mounting  

Normal operating range... 0-10 pH with excursions to 12 pH

Temperature range... 0-140 Celsius.

Temperature compensation... Pt 100 RTD

Pressure Rated.... 1 to 9 Bar 

Wetted Surfaces.... Glass Coated, Teflon gasket

Electrolyte flow rate....0.2cc/hr at 1 Bar over pressure

Information Request Form

                              

 

 